FLIR ADGiLE™-Automated Methane Monitoring Solution with Optical Gas Imaging

CONTINUOUS OPERATION – DAY OR NIGHT: Operating 24/7 for continuous monitoring of methane emissions. This continuous monitoring is critical for sites where emissions can occur at any time.

ENHANCED METHANE VISUALIZATION; Advanced leak detection analytics to precisely visualize and pinpoint methane emissions, enabling you to detect leaks quickly and efficiently.

ADVANCED SITUATIONAL AWARENESS: Accurately distinguish between operational leaks and fugitive leak emissions to improve safety and operational efficiency.

POAExcluding Tax

Request a Quote

Description

Description

The FLIR ADGiLE™ system is an advanced methane detection solution designed to provide continuous and autonomous monitoring of gas leaks.

Integrating over a decade of FLIR’s advanced Optical Gas Imaging (OGI) technology, ADGiLE enables operators to quickly identify and address methane emissions, ensuring safety and compliance with environmental initiatives.

This system significantly reduces the need for manual inspections, offering real-time alerts and visual insights that help users act swiftly to prevent hazards and maintain operational efficiency.

To order this item please contact us directly:
Email: sales@butlertech.ie
Phone: +353 1 6292620

Specification

IR Resolution

320 × 240 pixels

Thermal Sensitivity/NETD

<25 mK at 30°C (86°F)

Spectral Range

Uncooled microbolometer: 7.0 µm to 8.5 µm

IMAGING & OPTICAL

Detector Pitch

25 µm

Field of view (FOV)

25° × 19°

Field of view (FOV) – Focal Length

18 mm (0.71 in)

f-number

1.04

Focus

  • One-shot contrast
    • Motorized
    • Manual

Gas Sensitivity [NECL]

CH4: <100 ppm × m
(ΔT = 10°C, Distance = 1 m)

Image Frequency

30 Hz

IR Resolution

320 × 240 pixels

Lens Identification

Automatic

Minimum Focus Distance

Without MSX: 0.3 m (0.98 ft)
With MSX: 0.65 m (2.1 ft)

Spatial resolution (IFOV)

1.4 mrad/pixel

Spectral Range

Uncooled microbolometer: 7.0 µm to 8.5 µm

Thermal Sensitivity/NETD

<25 mK at 30°C (86°F)

MEASUREMENT & ANALYSIS

Accuracy

Range 1: -20°C to 80°C (-4°F to 176°F) ±3°C (±5°F)
Range 2: 0°C to 250°C (212°F to 482°F) / 0°C to 100°C (32°F to 212°F):±3°C / 100° to 250°C (212° to 482°F):±3%
Range 3: 100°C to 500°C (212°F to 932°F):±3%

Atmospheric transmission correction

Based on inputs of distance, atmospheric temperature, and relative humidity

Emissivity Correction

Variable from 0.01 to 1.0

External Optics & Windows Correction

Based on input of optics/window transmission and temperature

Measurement Corrections

Global object parameters

Object Temperature Range

Range 1: -20°C to 80°C (-4°F to 176°F)
Range 2: 0°C to 250°C (212°F to 482°F)
Range 3: 100°C to 500°C (212°F to 932°F)

Reflected apparent temperature correction

Based on input of reflected temperature

GENERAL

Housing material

Aluminium

Included

Thermal camera in protective housing
Extra cable glands for auxiliary cables
Control cabinet (incl. Edge PC)
Adapter bracket
Screw kit
Power/Com cable
Ethernet cable, RJ45
Cardboard box environmental housing fixed
Insert cardboard box environmental housing
Printed documentation including the username and password for log in to the web interface of the camera

Size [L × W × H]

Camera: 510 mm × 177 mm × 229 mm (20.1 in × 6.97 in × 9.02 in)
Control unit (external): 700 mm × 530 mm × 265 mm (27.5 in × 20.8 in × 10.4 in)
Mounting plate: 535 mm × 430 mm (21.06 in × 16.9 in)

Weight

5.90 kg (13.0 lb)

POWER

External Power Operation

Compatible with IEEE 802.3af, IEEE 802.3at/PoE Plus

External Voltage

PoE Class 4 (25 W)

Power Consumption

21 W

ENVIRONMENTAL & CERTIFICATIONS

Corrosion

Salty fog resistance: ISO9227, to 1000 hours

EMC

EN 55032:2015 Emission Requirements
EN 55035:2017 Immunity Requirements
FCC – Title 47 CFR Part 15:2019
ICES-001 Issue 4:2014

Encapsulation

IP67

Humidity (Operating and Storage)

Relative humidity: from 5% up to 95%

Lens Transmission Correction

Automatic, based on signals from internal sensors

Operating Temperature Range

-30°C to 50°C (-22°F to 122°F)

Storage Temperature Range

IEC 68-2-1 and IEC 68-2-2, -40°C to 70°C (-104°F to 158°F) for 16 hours